De QATM Rockwell hardheidsmeter serie combineert een verfijnd ontwerp met technische innovatie. Een overvloed aan comfortfuncties maakt de bediening eenvoudig, veilig en snel. Moderne software en interfaces maken tijdbesparende automatisering en integratie van de hardheidsmeter in elk laboratorium mogelijk. Dankzij het grote testkrachtbereik kunnen Rockwell-tests worden uitgevoerd op veel verschillende materialen.
- Testmethoden: Rockwell, Brinell, Vickers
- Controle: C-frame met handmatige spindel
- Testmethoden: Rockwell, Brinell, Vickers
- Controle: Volledig automatisch
- Testmethoden: Rockwell, Brinell
- Controle: Siemens S7 PLC
- Geoptimaliseerde cyclustijd
Configureer uw QATM hardheidstester om overeen te komen met uw testmethode, testbelastingsbereik, automatisatieniveau en toepassingsvereisten.
QATM Rockwell Hardness Testers for HR Testing of Metals
QATM Rockwell hardness testers press a Rockwell indenter into a metal specimen under a preliminary force and an additional force and calculate the Rockwell hardness (HR) from the permanent depth difference. The Qness 150 CS, 150 CSA+ and 150/60 RCS are dedicated Rockwell testers; the universal Qness macro testers add Brinell, Vickers and Knoop. EN ISO 6508-1 and ASTM E18 define the method.
Key data of QATM Rockwell hardness testers
QATM Rockwell hardness testers measure metals with a 120° diamond cone or a tungsten carbide ball at total test forces from 147.1 N (HR15N) to 1,471 N (HRC and the other 150 kgf scales), with a preliminary force of 98.07 N or 29.42 N. The Rockwell scales available depend on the tester model; the table summarizes the key data.
| Attribute | Value |
|---|---|
| Test method and standards | Rockwell hardness testing (HR), evaluated from the permanent depth difference; EN ISO 6508-1, ASTM E18 |
| Rockwell scales | Qness 150 CS, 150 CSA+ and Qness C, E and A+ EVO: HRA to HRV and HR15, HR30, HR45 in the N, T, W, X and Y variants. Qness 150 RCS: HRC. Qness 60 RCS: HBT 2.5/62.5 (depth-based, not HBW) |
| Depth measurement | Direct depth-gauging system on the indenter axis (Qness 150 CS and 150 CSA+) |
Who the QATM Rockwell hardness testers are for
QATM Rockwell hardness testers are for quality-control and production laboratories, heat-treatment shops and incoming inspection that verify a specified Rockwell scale on metallic parts at defined test positions. The range extends from a compact C-frame tester to automated, PLC-controlled and universal macro testers.
For small test areas, thin layers or optical evaluation of the indentation, the Vickers and Knoop options of the QATM Qness micro testers are often the suitable choice; coarse castings and forgings suit Brinell.
QATM Rockwell hardness tester models and Rockwell scales
QATM offers dedicated Rockwell testers (Qness 150 CS, 150 CSA+, 150 RCS and 60 RCS) and universal testers that include Rockwell among several methods: the Qness 200 CS, three Qness EVO macro series and the Qness micro testers. The table lists the data published by QATM for each family.
| QATM model | Type, positioning and key dimensions | Test force range | Rockwell scales and methods published by QATM |
|---|---|---|---|
| Qness 150 CS | Dedicated Rockwell tester; C-frame with fixed test head, manual spindle positioning; test height 250 mm, throat depth 157 mm, maximum specimen weight 100 kg; software lists up to 999 results with statistics and tolerance limits | 9.81–2,452 N (1–250 kgf) | HRA to HRV; HR15, HR30, HR45 (N, T, W, X, Y); HBT and HVT, not to standard |
| Qness 150 CSA+ | Dedicated Rockwell tester; automated XY slide and motorized height adjustment for series tests on parts of identical height; test height 140 mm, throat depth 238 mm, maximum specimen weight 100 kg | 9.81–2,450 N (1–250 kgf) | As Qness 150 CS |
| Qness 150 RCS | Dedicated production tester; Siemens S7 PLC control; test height 180 mm, horizontal reach 180 mm | 1,471.5 N (150 kgf) | HRC |
| Qness 60 RCS | As Qness 150 RCS; depth-based Brinell variant | 613.1 N (62.5 kgf) | HBT 2.5/62.5, not HBW according to EN ISO 6506-1 |
| Qness 200 CS | Macro universal tester; fixed test head, manual spindle positioning | ||
| Qness 250/750/3000 C EVO | Macro universal tester; C-frame with fixed test head and moving spindle; test height 395 mm, throat depth 220 mm | Qness 250: 9.81–2,450 N. Qness 750: 2.94–7,358 N. Qness 3000: 2.94–29,430 N | HRA to HRV; HR15, HR30, HR45 (N, T, W, X, Y) |
| Qness 250/750/3000 E EVO | Macro universal tester; fixed specimen support with motorized test head; test height 510 mm, throat depth 320 mm | As C EVO | As C EVO |
| Qness 250/750/3000 A+ EVO | Macro universal tester; automated XYZ sequences across positions and specimen heights; test height 362 mm, throat depth 320 mm | As C EVO | As C EVO |
| Qness 10/60 M, Qness 10/60 A+ and Qness 60 A+ EVO | Micro tester; Rockwell module by option | Qness 10: 0.196–98.07 N. Qness 60: 0.00245–612.92 N |
Test forces are shown as published in the QATM data sheets (9.81 m/s²); EN ISO 6508-1 nominal forces use 9.80665 m/s², for example 1,471 N for HRC. HBT and HVT are depth-based variants of Brinell and Vickers testing that QATM states are not according to standards; they do not replace HBW or HV tests.
How do you choose a QATM Rockwell hardness tester?
Choose a QATM Rockwell hardness tester by the Rockwell scale the specification requires, then by specimen size and weight, the number of test positions, the production cycle time and the documentation needs. The total test force of the scale sets the minimum model class; the table maps typical requirements to QATM starting points.
| Requirement | QATM starting point |
|---|---|
| Specified Rockwell scale, single test positions, laboratory use | Qness 150 CS |
| Automated series tests on parts of identical height | Qness 150 CSA+; Qness A+ EVO series series for varying specimen heights |
| PLC-controlled HRC production checks | Qness 150 RCS (inline solutions by agreement) |
| Depth-based HBT production checks, not to standard | Qness 60 RCS (HBT 2.5/62.5) |
| Rockwell together with Brinell, Vickers and Knoop on one tester | Qness 250/750/3000 C EVO, Qness 250/750/3000 E EVO or Qness 250/750/3000 A+ EVO; Qness 200 CS |
| Rockwell together with micro Vickers and Knoop on small specimens | Qness 10/60 M, Qness 10/60 A+, Qness 60 A+ EVO (Rockwell by option) |
How does Rockwell hardness testing work?
Rockwell hardness testing reads hardness from penetration depth, not from the optical size of an indentation. The indenter is pressed into the specimen under a preliminary force, an additional force is applied and removed, and the permanent depth difference at the preliminary force gives the Rockwell hardness (HR). EN ISO 6508-1 and ASTM E18 define the procedure.
- Define the test requirement: Rockwell scale, reporting requirements and governing specification.
- Apply the preliminary force F0: the indenter contacts the specimen and F0 sets the reference depth t0; stable support matters because movement during the cycle changes the depth.
- Apply the additional force F1: the tester adds F1 under the force–time conditions of the selected scale, and the indenter penetrates a further depth Δt.
- Return to the preliminary force F0: after F1 is removed, the indenter recovers elastically by tel and the permanent depth difference h remains.
- Read the result: the tester converts h into the Rockwell hardness for the selected scale.
- Document the result: the HR value with its complete scale designation.
The preliminary force reduces the influence of the surface but does not eliminate oxide layers, hardened layers, vibration or unsuitable specimen support.
How is Rockwell hardness (HR) calculated?
Rockwell hardness is a constant N minus the permanent depth difference h divided by the scale division S: HR = N − h / S. For HRC, N = 100 and S = 0.002 mm; the constants differ between scales, as the next paragraph shows.
Ball scales such as HRBW use N = 130 and S = 0.002 mm; superficial scales use N = 100 and S = 0.001 mm. Never mix the constants between scales.
How is a Rockwell hardness result written?
A Rockwell result states the HR value and the scale designation; ball scales add the indenter material as a suffix. In 60 HRC, 60 is the value, HR the generic marker and C the scale. HRBW carries the suffix W for a tungsten carbide ball, which is never appended to the diamond cone scale HRC.
Example: a permanent depth difference h of 0.12 mm gives HRC = 100 − 0.12 / 0.002 = 40, reported as 40 HRC.
Which Rockwell scale should you use?
Select the Rockwell scale from the drawing, product specification or standard; the scale fixes the indenter and the total test force. Diamond cone scales (HRA, HRC, HR15N, HR30N, HR45N) use a 120° cone with a nominal tip radius of 0.2 mm; ball scales use a tungsten carbide ball of 1.5875 mm or 3.175 mm. The table lists the common scales.
| Scale | Indenter | Total test force (N) | Nominal force (kgf) | Typical materials |
|---|---|---|---|---|
| HRA | 120° diamond cone | 588.4 | 60 | Cemented carbides, thin steel, shallow case-hardened steel |
| HRBW | 1.5875 mm ball | 980.7 | 100 | Copper alloys, soft steel, aluminum alloys, malleable iron |
| HRC | 120° diamond cone | 1,471 | 150 | Steel, hard cast iron, titanium, deep case-hardened steel |
| HR15N, HR30N, HR45N | 120° diamond cone | 147.1, 294.2, 441.3 | 15, 30, 45 | Thin or small specimens, hard materials |
| HR15TW, HR30TW, HR45TW | 1.5875 mm ball | 147.1, 294.2, 441.3 | 15, 30, 45 | Thin or small specimens, soft materials |
What conditions must be met for standard-compliant Rockwell hardness testing?
Standard-compliant Rockwell hardness testing requires controlled test conditions: preliminary force, specimen thickness, indentation spacing, edge distance, force application and dwell times and temperature. EN ISO 6508-1 and ASTM E18 define the values listed in the table; the governing specification or customer agreement may require different values and takes precedence.
| Parameter | Requirement |
|---|---|
| Preliminary force F0 | 98.07 N (10 kgf) for regular scales; 29.42 N (3 kgf) for superficial scales |
| Specimen or tested-layer thickness | EN ISO 6508-1: at least 10 × the permanent depth difference h for the diamond cone and at least 15 × h for a ball, unless a thinner specimen is shown not to affect the result. ASTM E18: at least 10 × h for both indenters |
| Distance between indentation centers and to the specimen edge | |
| Force application and dwell time | |
| Test temperature | 10–35 °C |
The force ranges above describe the overall capabilities of each tester across its supported test methods. For Brinell testing, use the nominal forces listed in EN ISO 6506-1 or ASTM E10, as shown in the HBW scale table below. Available scales depend on the installed indenter, optics, software and verified configuration.
When should you choose Rockwell instead of Brinell, Vickers or Knoop hardness testing?
Choose Rockwell hardness testing for routine quality control of metallic parts when the specification calls for an HR scale: the result is read from penetration depth, with no optical measurement of an indentation. Brinell, Vickers and Knoop suit other test tasks, as the table shows.
| Method | Indenter and evaluated quantity | Typical use | Principal standards |
|---|---|---|---|
| Rockwell (HR) | Diamond cone or ball, depending on the scale; difference in penetration depth | Routine quality control against a specified HR scale; no optical measurement | EN ISO 6508-1; ASTM E18 |
| Brinell (HBW) | Tungsten carbide ball; mean diameter of the permanent indentation, measured optically | Castings, forgings and other coarse or inhomogeneous metals | EN ISO 6506-1; ASTM E10 |
| Vickers (HV) | Square-based diamond pyramid; both diagonals, measured optically | Micro to macro test forces; small to medium test areas | EN ISO 6507-1; ASTM E384 |
| Knoop (HK) | Elongated diamond pyramid; long diagonal, measured optically | Thin layers, coatings, hardness gradients, brittle materials | EN ISO 4545-1; ASTM E384; ASTM C1326 (advanced ceramics) |
Can Rockwell values be converted to Brinell or Vickers values?
Only as an estimate. EN ISO 18265 and ASTM E140 give conversions for specified materials and conditions; a converted value is identified as converted, is not a direct Rockwell, Brinell or Vickers measurement and does not replace a required test. The Qness 150 CS and 150 CSA+ offer integrated conversions per both standards.
Where is Rockwell hardness testing used?
Rockwell hardness testing is used as a practical quality-control measurement for metallic parts: production inspection, acceptance testing, incoming inspection and checks of heat-treated parts, fasteners and automotive parts. The scale, test location, preparation and acceptance criteria come from the product or process documentation.
Which standards apply to Rockwell hardness testing?
EN ISO 6508-1 and ASTM E18 specify Rockwell hardness testing of metallic materials, and QATM lists both for its Rockwell testers. The governing specification determines the standard, the edition and the test conditions; the two standards differ in details, so compare them before assuming equivalence.
| Standard | Scope |
|---|---|
| EN ISO 6508-1 | Rockwell hardness test, part 1: test method |
| EN ISO 6508-2 and -3 | Rockwell hardness test, part 2: verification and calibration of testing machines; part 3: calibration of reference blocks |
| ASTM E18 | Rockwell hardness of metallic materials |
Request a quote for a QATM Rockwell hardness tester
QATM reviews the specimen material, geometry, governing specification, expected inspection volume and handling constraints to identify a suitable Rockwell hardness tester configuration. Include the Rockwell scale, the largest specimen size, the number of test positions and the required documentation in your request, and confirm indenter, test force range and fixtures before purchase.
Rockwell Hardheidstester - FAQ
What is a Rockwell hardness tester used for?
A Rockwell hardness tester is used to measure the hardness of materials, particularly metals and polymers. It provides a quick and direct hardness reading, making it ideal for quality control and material testing in manufacturing environments.
How does the Rockwell hardness test work?
The Rockwell test involves pressing an indenter (either a steel ball or a diamond cone) into the material's surface under a preliminary minor load. Then, an additional major load is applied, and the depth of penetration is measured after removing the major load. The hardness value is determined from the depth of the indentation.
What are the different scales in Rockwell hardness testing?
Rockwell hardness testing features multiple scales, such as A, B, C, etc., each using different indenter types and loads suitable for various materials. The most common scale for metals is the Rockwell C scale (HRC), which uses a diamond cone indenter and is often used for harder materials like steel.
What are the advantages of using a Rockwell hardness tester?
Rockwell hardness testers offer rapid and straightforward testing with direct readouts, minimal sample preparation, and a wide range of scales to accommodate different materials. They are suitable for both laboratory and shop floor environments
What factors can affect the accuracy of a Rockwell hardness test?
Accuracy can be influenced by factors such as surface finish, sample thickness, and proper alignment of the indenter. It's crucial to use the correct scale for the material being tested and ensure the equipment is well-calibrated and maintained.